@Cofi Aha, evo sada ispisa…
toske@toske-945GZM-S2:~$ sudo smartctl -a /dev/sda
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.16.0-24-generic] (local build)
Copyright © 2002-13, Bruce Allen, Christian Franke,
www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar Blue Serial ATA
Device Model: WDC WD1600AAJS-22PSA0
Serial Number: WD-WMAP99272112
LU WWN Device Id: 5 0014ee 0aaf5161c
Firmware Version: 05.06H05
User Capacity: 159,905,567,744 bytes [159 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Sat Nov 8 18:58:06 2014 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4380) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 58) minutes.
Conveyance self-test routine
recommended polling time: ( 6) minutes.
SCT capabilities: (0x103f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 2
3 Spin_Up_Time 0x0003 158 150 021 Pre-fail Always - 3091
4 Start_Stop_Count 0x0032 096 096 000 Old_age Always - 4080
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x000e 200 200 051 Old_age Always - 0
9 Power_On_Hours 0x0032 080 080 000 Old_age Always - 14803
10 Spin_Retry_Count 0x0012 100 100 051 Old_age Always - 0
11 Calibration_Retry_Count 0x0012 100 100 051 Old_age Always - 0
12 Power_Cycle_Count 0x0032 096 096 000 Old_age Always - 4040
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 332
193 Load_Cycle_Count 0x0032 199 199 000 Old_age Always - 4102
194 Temperature_Celsius 0x0022 103 091 000 Old_age Always - 40
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 4216
200 Multi_Zone_Error_Rate 0x0008 200 200 051 Old_age Offline - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
1 Short offline Completed without error 00% 13186 -
2 Short offline Completed without error 00% 12950 -
3 Extended offline Completed without error 00% 12715 -
4 Extended offline Completed without error 00% 12708 -
5 Extended offline Completed without error 00% 12014 -
6 Short offline Interrupted (host reset) 90% 12011 -
7 Short offline Completed without error 00% 10801 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.